STM32F439xx HAL User Manual
Functions
Falling_Trigger_Management
EXTI Exported Functions

Functions

__STATIC_INLINE void LL_EXTI_EnableFallingTrig_0_31 (uint32_t ExtiLine)
 Enable ExtiLine Falling Edge Trigger for Lines in range 0 to 31.
__STATIC_INLINE void LL_EXTI_DisableFallingTrig_0_31 (uint32_t ExtiLine)
 Disable ExtiLine Falling Edge Trigger for Lines in range 0 to 31.
__STATIC_INLINE uint32_t LL_EXTI_IsEnabledFallingTrig_0_31 (uint32_t ExtiLine)
 Check if falling edge trigger is enabled for Lines in range 0 to 31.

Function Documentation

__STATIC_INLINE void LL_EXTI_DisableFallingTrig_0_31 ( uint32_t  ExtiLine)

Disable ExtiLine Falling Edge Trigger for Lines in range 0 to 31.

Note:
The configurable wakeup lines are edge-triggered. No glitch must be generated on these lines. If a Falling edge on a configurable interrupt line occurs during a write operation in the EXTI_FTSR register, the pending bit is not set. Rising and falling edge triggers can be set for the same interrupt line. In this case, both generate a trigger condition.
Reference Manual to LL API cross reference:
FTSR FTx LL_EXTI_DisableFallingTrig_0_31
Parameters:
ExtiLineThis parameter can be a combination of the following values:
Note:
(*): Available in some devices
Please check each device line mapping for EXTI Line availability
Return values:
None

Definition at line 720 of file stm32f4xx_ll_exti.h.

Referenced by LL_EXTI_Init().

__STATIC_INLINE void LL_EXTI_EnableFallingTrig_0_31 ( uint32_t  ExtiLine)

Enable ExtiLine Falling Edge Trigger for Lines in range 0 to 31.

Note:
The configurable wakeup lines are edge-triggered. No glitch must be generated on these lines. If a falling edge on a configurable interrupt line occurs during a write operation in the EXTI_FTSR register, the pending bit is not set. Rising and falling edge triggers can be set for the same interrupt line. In this case, both generate a trigger condition.
Reference Manual to LL API cross reference:
FTSR FTx LL_EXTI_EnableFallingTrig_0_31
Parameters:
ExtiLineThis parameter can be a combination of the following values:
Note:
(*): Available in some devices
Please check each device line mapping for EXTI Line availability
Return values:
None

Definition at line 678 of file stm32f4xx_ll_exti.h.

Referenced by LL_EXTI_Init().

__STATIC_INLINE uint32_t LL_EXTI_IsEnabledFallingTrig_0_31 ( uint32_t  ExtiLine)

Check if falling edge trigger is enabled for Lines in range 0 to 31.

Reference Manual to LL API cross reference:
FTSR FTx LL_EXTI_IsEnabledFallingTrig_0_31
Parameters:
ExtiLineThis parameter can be a combination of the following values:
Note:
(*): Available in some devices
Please check each device line mapping for EXTI Line availability
Return values:
Stateof bit (1 or 0).

Definition at line 756 of file stm32f4xx_ll_exti.h.